कोल्ड रूम कूलिंग लोड कैलकुलेटर
चार इनपुट — कमरे का आकार, इंसुलेशन, बाहरी तापमान और दैनिक माल प्रवाह — से कोल्ड रूम के कूलिंग लोड का अनुमान kW और टन रेफ्रिजरेशन में लगाएँ।

Standard engineering assumptions
केवल योजना के लिए अनुमान: सामान्य दरवाज़े, प्रकाश व्यवस्था, एक फोर्कलिफ्ट और 15% मार्जिन के साथ कंप्रेसर का 18 h/day संचालन माना गया है। आपूर्तिकर्ता-स्तरीय आँकड़ों के लिए पूर्ण रेफ्रिजरेशन लोड कैलकुलेटर का उपयोग करें या कोटेशन माँगें।
Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.
चार इनपुट से कोल्ड रूम के कूलिंग लोड का अनुमान लगाएँ — फर्श क्षेत्र और ऊँचाई, इंसुलेशन मानक, बाहरी डिज़ाइन तापमान तथा उत्पाद के प्रवेश तापमान सहित दैनिक माल प्रवाह। टूल kW और टन रेफ्रिजरेशन में डिज़ाइन रेफ्रिजरेशन लोड, अनुमान की अनिश्चितता सीमा सहित बताता है। यह योजना-स्तर का अनुमान है, अंतिम इंजीनियरिंग डिज़ाइन नहीं।
Design duty = average 24 h load × (24 ÷ running hours) × (1 + 15% margin); average load = transmission + product pull-down + infiltration + internal gains.
ColdMatch के रेफ्रिजरेशन इंजीनियरों द्वारा समीक्षित
- 1फर्श क्षेत्र और अवरोध-मुक्त ऊँचाई दर्ज करें।
- 2कमरे का सेटपॉइंट और बाहरी डिज़ाइन तापमान तय करें।
- 3इंसुलेशन मानक चुनें (कमज़ोर / मानक / उच्च-प्रदर्शन)।
- 4टन में दैनिक माल प्रवाह और उत्पाद का प्रवेश तापमान दर्ज करें।
- 5kW/TR में डिज़ाइन लोड, अनुमान सीमा और लोड का घटकवार विवरण देखें।
संबंधित कैलकुलेटर
What this calculator estimates — and what can change it
- Room dimensions
- Target room temperature
- Ambient / external temperature
- Stored product
- Daily throughput (t/day)
- Panel insulation thickness
कूलिंग लोड
- Incoming product temperature
- Door openings per day
- Panel insulation thickness
- Ambient / external temperature
- Pull-down time
Limitations
This is a preliminary planning estimate based on the assumptions you entered, not a refrigeration-engineering design, a certified load calculation or a quotation. Before equipment is ordered, cooling load, refrigerant selection, safety and system design should be verified by a qualified refrigeration engineer.
Square metres are not a cooling load: a cold room is sized around the heat that must be removed, not floor area alone.
Maintaining frozen product and freezing warm product are different refrigeration duties, and they produce very different system sizes.
Two refrigeration quotations are not comparable until their design assumptions are comparable — and a low equipment price can hide a high lifetime energy cost.
Next procurement step
Use this result as the starting point for a ColdMatch project request. Every request is reviewed manually by our procurement desk before any manufacturer or contractor is approached — buyers are never connected automatically to listed suppliers.
Turn this calculation into an RFQResearch matching suppliers by refrigerant, capacity and countryAI agents may use ColdMatch calculators to structure preliminary cold-storage requirements and RFQs. Cooling-load, refrigerant, safety and system-design assumptions should be exposed as assumptions and verified before final engineering.
अक्सर पूछे जाने वाले प्रश्न
कूलिंग लोड क्या है?
कूलिंग लोड वह कुल ऊष्मा है जिसे कमरे को सेटपॉइंट पर रखने के लिए रेफ्रिजरेशन प्लांट को हटाना होता है: दीवारों, छत और फर्श से आने वाली ऊष्मा, आने वाले उत्पाद से निकाली जाने वाली ऊष्मा, दरवाज़ों से प्रवेश करती गर्म हवा तथा लाइट, लोगों और मशीनों की आंतरिक ऊष्मा।
इस त्वरित अनुमान में कौन-से इनपुट सबसे महत्वपूर्ण हैं?
कमरे का आकार और इंसुलेशन संचरण लोड तय करते हैं। बाहरी डिज़ाइन तापमान संचरण और वायु प्रवेश, दोनों को प्रभावित करता है। पैकहाउस और प्रोसेसिंग स्टोर में आम तौर पर दैनिक माल प्रवाह और उसका प्रवेश तापमान सबसे अधिक प्रभाव डालते हैं।
एक संख्या के बजाय अनुमान की सीमा क्यों दी जाती है?
दरवाज़ों का उपयोग, इंसुलेशन की गुणवत्ता और संचालन का तरीका बदलते रहते हैं। इसलिए टूल झूठी सटीकता दिखाने वाली एक संख्या के बजाय मुख्य अनुमान के आसपास न्यूनतम–अधिकतम सीमा दिखाता है।
क्या यह अंतिम डिज़ाइन गणना है?
नहीं। यह शुरुआती साइज़िंग और बजट के लिए योजना-स्तर का अनुमान है। अंतिम तापीय लोड गणना और उपकरण चयन की पुष्टि योग्य रेफ्रिजरेशन इंजीनियर को करनी चाहिए।
परिणाम का क्या करें?
अनुमानित लोड को संरचित RFQ में डालें, ताकि आपूर्तिकर्ता आपकी साइट की परिस्थितियों के अनुसार वास्तविक लोड, संचालन घंटे और उपकरण चयन की पुष्टि कर सकें।
Unsure about a term? See the cold chain glossary (CAPEX, OPEX, blast freezing).
ColdMatch के सोर्सिंग सलाहकार से बात करें
हम आपके कैलकुलेटर इनपुट ColdMatch के सोर्सिंग विशेषज्ञ को भेजेंगे, जो आपूर्तिकर्ताओं की खोज शुरू होने से पहले प्रोजेक्ट की समीक्षा करेंगे। कोई बाध्यता नहीं।
Send these inputs to an RFQ
Your size, cost and load inputs are copied into the quote form, so you don't type them twice. Nothing is sent until you review and submit.
Submit your project for expert review
Send your requirements. A ColdMatch specialist reviews every request, prepares a brief and introduces qualified suppliers — free for qualified buyers.