熱負荷計算|冷蔵・冷凍倉庫の必要能力を試算
床面積・天井高、断熱仕様、外気設計温度、1日の処理量(入荷温度含む)の4項目から、冷蔵倉庫の冷却負荷をkWおよび冷凍トンで概算します。あくまで計画段階の試算であり、最終設計ではありません。

Standard engineering assumptions
本結果はあくまで計画段階の試算です。標準的な扉・照明・フォークリフト1台の使用、圧縮機の1日18時間稼働、15%の余裕を前提としています。サプライヤー提出用の正式な数値には、詳細版の冷凍熱負荷計算ツールをご利用いただくか、見積もりをご依頼ください。
Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.
本ツールは、床面積・天井高、断熱仕様、外気設計温度、1日の処理量(入荷温度含む)の4項目から冷蔵倉庫の冷却負荷を概算します。結果として、設計冷却能力(kWおよび冷凍トン)と計画上の想定幅を表示します。あくまで計画段階の試算であり、最終的な工学的設計ではありません。
設計能力=24時間平均負荷×(24÷稼働時間)×(1+15%の余裕);平均負荷=貫流負荷+製品予冷負荷+侵入負荷+内部発熱
ColdMatchの冷凍技術エンジニアが監修
- 1床面積と有効天井高を入力します。
- 2設定温度と外気設計温度を設定します。
- 3断熱仕様(低断熱/標準/高性能)を選択します。
- 41日の処理量(トン)と製品の入荷温度を入力します。
- 5設計能力(kW/TR)、想定幅、負荷の内訳を確認します。
What this calculator estimates — and what can change it
- Room dimensions
- Target room temperature
- Ambient / external temperature
- Stored product
- Daily throughput (t/day)
- Panel insulation thickness
冷却負荷
- Incoming product temperature
- Door openings per day
- Panel insulation thickness
- Ambient / external temperature
- Pull-down time
Limitations
This is a preliminary planning estimate based on the assumptions you entered, not a refrigeration-engineering design, a certified load calculation or a quotation. Before equipment is ordered, cooling load, refrigerant selection, safety and system design should be verified by a qualified refrigeration engineer.
Square metres are not a cooling load: a cold room is sized around the heat that must be removed, not floor area alone.
Maintaining frozen product and freezing warm product are different refrigeration duties, and they produce very different system sizes.
Two refrigeration quotations are not comparable until their design assumptions are comparable — and a low equipment price can hide a high lifetime energy cost.
Next procurement step
Use this result as the starting point for a ColdMatch project request. Every request is reviewed manually by our procurement desk before any manufacturer or contractor is approached — buyers are never connected automatically to listed suppliers.
Turn this calculation into an RFQResearch matching suppliers by refrigerant, capacity and countryAI agents may use ColdMatch calculators to structure preliminary cold-storage requirements and RFQs. Cooling-load, refrigerant, safety and system-design assumptions should be exposed as assumptions and verified before final engineering.
よくある質問
熱負荷計算とは何ですか?冷房負荷計算との違いは?
熱負荷計算は、壁・天井・床からの貫流熱、製品の冷却熱、扉開閉による外気侵入、照明・ファン・人員などの内部発熱を合計し、必要な冷却能力(kW)を求める計算です。冷房負荷計算は主に事務所や住宅の空調向けで、冷蔵倉庫では製品負荷と低温条件を加味する点が異なります。
冷却負荷とは何ですか?
冷却負荷とは、冷蔵倉庫を設定温度に保つために冷凍設備が取り除く必要のある総熱量のことです。壁・屋根・床からの貫流熱、入荷する製品を冷やすための熱、扉の開閉で入り込む外気の熱、照明・人・機器などによる内部発熱が含まれます。
この簡易試算で特に重要な入力項目は何ですか?
床面積と断熱仕様が貫流負荷を決め、外気設計温度は貫流負荷と侵入負荷の両方に影響します。加工場や物流倉庫では、1日の処理量とその入荷温度が負荷全体を左右することが多くなります。
なぜ1つの数値ではなく幅で表示されるのですか?
扉の使用状況、断熱の施工品質、運用パターンは現場ごとに異なるため、誤った精度の印象を与える単一の数値ではなく、低め〜高めの想定幅を表示しています。
これは最終的な設計計算ですか?
いいえ。初期段階のサイズ検討や予算策定のための計画用試算です。最終的な熱負荷計算と設備選定は、有資格の冷凍技術者による確認が必要です。
算出結果はどのように活用すればよいですか?
試算した冷却負荷を構造化されたRFQに転記し、サプライヤーに現地条件に基づく実際の負荷、稼働時間、設備選定を確認してもらってください。
Unsure about a term? See the cold chain glossary (CAPEX, OPEX, blast freezing).
ColdMatchの調達アドバイザーに相談する
計算結果はColdMatchの調達専門スタッフに送られ、サプライヤー選定を始める前にプロジェクト内容を確認します。ご相談は無料で、契約義務は一切発生しません。
Submit your project for expert review
Send your requirements. A ColdMatch specialist reviews every request, prepares a brief and introduces qualified suppliers — free for qualified buyers.