열부하 계산|냉동·냉장창고 필요 용량(kW)
네 가지 입력값 — 창고 크기, 단열 수준, 설계 외기온도, 일일 처리량 — 으로 냉장창고의 냉각부하를 kW와 냉동톤(TR)으로 추정합니다. 오차 범위를 포함한 초기 기획용 추정치입니다.

Standard engineering assumptions
기획용 추정치입니다: 일반적인 도어, 조명, 지게차 1대, 압축기 18시간/일 가동, 15% 여유율을 가정합니다. 공급업체 제출용 수치가 필요하면 전체 냉동 열부하 계산기를 사용하거나 견적을 요청하세요.
냉동창고와 자재에 관한 구매자 질문 →Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.
냉장창고의 냉각부하는 창고 면적·높이, 단열 수준, 설계 외기온도, 일일 처리량이라는 네 가지 값으로 추정합니다. 이 도구는 설계 냉동부하를 kW와 냉동톤(TR)으로 산출하며 기획용 오차범위를 함께 제시합니다. 이는 기획 단계의 추정치이며 최종 엔지니어링 설계가 아닙니다.
설계부하 = 24시간 평균부하 × (24 ÷ 가동시간) × (1 + 15% 여유율); 평균부하 = 전도 + 제품예냉 + 침기 + 내부발열
ColdMatch 냉동 엔지니어 검토 완료
- 1바닥면적과 유효 천장고를 입력하세요.
- 2설정 온도와 설계 외기온도를 지정하세요.
- 3단열 수준(불량/표준/고성능)을 선택하세요.
- 4일일 처리량(톤)과 제품 반입 온도를 입력하세요.
- 5산출된 설계부하(kW/TR), 기획 범위, 부하 구성 비율을 확인하세요.
What this calculator estimates — and what can change it
- Room dimensions
- Target room temperature
- Ambient / external temperature
- Stored product
- Daily throughput (t/day)
- Panel insulation thickness
냉각부하
- Incoming product temperature
- Door openings per day
- Panel insulation thickness
- Ambient / external temperature
- Pull-down time
Limitations
This is a preliminary planning estimate based on the assumptions you entered, not a refrigeration-engineering design, a certified load calculation or a quotation. Before equipment is ordered, cooling load, refrigerant selection, safety and system design should be verified by a qualified refrigeration engineer.
Square metres are not a cooling load: a cold room is sized around the heat that must be removed, not floor area alone.
Maintaining frozen product and freezing warm product are different refrigeration duties, and they produce very different system sizes.
Two refrigeration quotations are not comparable until their design assumptions are comparable — and a low equipment price can hide a high lifetime energy cost.
Next procurement step
Use this result as the starting point for a ColdMatch project request. Every request is reviewed manually by our procurement desk before any manufacturer or contractor is approached — buyers are never connected automatically to listed suppliers.
Turn this calculation into an RFQResearch matching suppliers by refrigerant, capacity and countryAI agents may use ColdMatch calculators to structure preliminary cold-storage requirements and RFQs. Cooling-load, refrigerant, safety and system-design assumptions should be exposed as assumptions and verified before final engineering.
자주 묻는 질문
열부하 계산은 어떻게 하나요?
벽·천장·바닥 관류열, 제품 냉각 부하, 문 개폐에 따른 외기 침입, 조명·팬·지게차·작업자 등 내부 발열을 합산한 뒤 10–20%의 안전율을 더합니다. 이 계산기는 냉동창고 열부하를 kW로 1차 추정합니다.
냉각부하란 무엇인가요?
냉각부하는 창고를 설정 온도로 유지하기 위해 냉동설비가 제거해야 하는 총 열량입니다. 벽·지붕·바닥을 통한 전도열, 반입 제품에서 빼앗는 열, 도어를 통해 들어오는 더운 공기, 조명·인원·장비의 내부 발열로 구성됩니다.
이 간이 추정에서 가장 중요한 입력값은 무엇인가요?
창고 크기와 단열 수준이 전도 부하를 결정하고, 설계 외기온도는 전도와 침기 모두에 영향을 미치며, 일일 처리량과 반입 온도는 포장·가공 창고에서 대개 지배적인 요소입니다.
왜 단일 수치가 아니라 범위로 표시되나요?
도어 사용 패턴, 단열 품질, 운영 방식이 현장마다 다르기 때문에, 잘못된 정밀도를 암시하는 단일 수치 대신 저–고 범위를 제공합니다.
이것이 최종 설계 계산인가요?
아니요. 초기 규모 산정과 예산 책정을 위한 기획용 추정치입니다. 최종 열부하 계산과 설비 선정은 자격을 갖춘 냉동 엔지니어가 확인해야 합니다.
결과를 어떻게 활용해야 하나요?
산출된 부하를 구조화된 RFQ에 옮겨 담아 공급업체가 실제 부하, 가동시간, 설비 사양을 현장 조건에 맞게 확인하도록 하세요.
Unsure about a term? See the cold chain glossary (CAPEX, OPEX, blast freezing).
ColdMatch 소싱 전문가와 상담하기
입력하신 계산 값을 ColdMatch 소싱 전문가에게 전달하며, 공급업체 조사를 시작하기 전에 프로젝트를 검토합니다. 의무 사항은 없습니다.
Submit your project for expert review
Send your requirements. A ColdMatch specialist reviews every request, prepares a brief and introduces qualified suppliers — free for qualified buyers.