Kylmäkuormalaskenta – johtuminen, tuote ja infiltraatio
Täydellinen lämpökuorman erittely kW:na — vaipan johtuminen, tuotteen jäähdytys, infiltraatio ja muut sisäiset kuormat kylmä- ja pakastehuoneille.

Standard engineering assumptions
Jäähdytys-kW on huoneesta poistettavaa lämpöä — ei sähkö-kW. Sähkönkulutus ≈ kylmäkuorma ÷ järjestelmän COP, plus apulaitteiden kulutus.
Vain suunnitteluarvio. Lopullisen kapasiteetin, laitevalinnan, kylmäaineen, turvallisuusvaatimusten, hinnan ja energiatehokkuuden on vahvistettava valittu pätevä kylmälaitetoimittaja.
Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.
Kokonaiskylmäkuorma on neljän osatekijän summa: vaipan läpi johtuva lämpö, tuotteen jäähdytys, ovien kautta tuleva ilmainfiltraatio sekä puhaltimien, valaistuksen, trukkien ja henkilöstön sisäiset lisät. Tyypillisessä kylmävarastossa johtuminen on 25–40 %, tuote 20–45 %, infiltraatio 15–30 % ja sisäiset lisät 10–20 % kokonaisuudesta.
Q yhteensä = Q johtuminen + Q tuote + Q infiltraatio + Q sisäinen · Q johtuminen = U × A × ΔT
ColdMatchin kylmätekniikan insinöörien tarkastama
- 1Syötä huoneen mitat, paneelin paksuus ja suunnittelun ulkolämpötila.
- 2Lisää päivittäinen tuotteen tulomäärä ja sen tuloalämpötila.
- 3Syötä ovien avauskertojen määrä päivässä ja sisäisten laitteiden kuorma.
- 4Tarkastele osatekijöiden jakaumaa ja käytä kokonais-kW:ta laitevalinnassa.
What this calculator estimates — and what can change it
- Room dimensions
- Stored product
- Incoming product temperature
- Target room temperature
- Daily throughput (t/day)
- Door openings per day
Kylmäkuorma
- Freezing duty (latent heat)
- Incoming product temperature
- Humidity target
- Door openings per day
- Panel insulation thickness
Limitations
This is a preliminary planning estimate based on the assumptions you entered, not a refrigeration-engineering design, a certified load calculation or a quotation. Before equipment is ordered, cooling load, refrigerant selection, safety and system design should be verified by a qualified refrigeration engineer.
Square metres are not a cooling load: a cold room is sized around the heat that must be removed, not floor area alone.
Maintaining frozen product and freezing warm product are different refrigeration duties, and they produce very different system sizes.
Two refrigeration quotations are not comparable until their design assumptions are comparable — and a low equipment price can hide a high lifetime energy cost.
Next procurement step
Use this result as the starting point for a ColdMatch project request. Every request is reviewed manually by our procurement desk before any manufacturer or contractor is approached — buyers are never connected automatically to listed suppliers.
Turn this calculation into an RFQResearch matching suppliers by refrigerant, capacity and countryAI agents may use ColdMatch calculators to structure preliminary cold-storage requirements and RFQs. Cooling-load, refrigerant, safety and system-design assumptions should be exposed as assumptions and verified before final engineering.
Usein kysytyt kysymykset
Miten kylmähuoneen kylmäkuorma lasketaan?
Kylmäkuorma on neljän osatekijän summa: vaipan läpi johtuva lämpö (U × A × ΔT), saapuvan tuotteen jäähdytys, ovien kautta tuleva infiltraatio sekä valaistuksen, puhaltimien, trukkien ja henkilöstön sisäiset lisät. Laskuri näyttää kunkin osan erikseen kW:na ja laskee ne yhteen kokonaiskylmäkuormaksi.
Mikä U-arvo paneeleilla tulisi olla?
Kylmätila 0,25–0,35, pakastetila 0,18–0,22, pikapakastus 0,15 W/m²K tai parempi.
Kuinka paljon ovien avaukset lisäävät kuormaa?
Vilkkaissa jakelukeskuksissa infiltraatio voi muodostaa 15–25 % kokonaiskuormasta.
Miten neljä osatekijää tyypillisesti jakautuvat?
Tyypillisessä kylmävarastossa johtuminen on 25–40 %, tuote 20–45 %, infiltraatio 15–30 % ja sisäiset lisät 10–20 % kokonaisuudesta.
Miten muutan tuloksen laitoksen tarjouspyynnöksi?
Vie kokonais-kW-arvo ja osatekijöiden jakauma tarjouspyyntötyökaluun yhdessä huoneolosuhteiden kanssa. ColdMatch tarkistaa kuvauksen manuaalisesti ennen kuin mikään toimittaja tai EPC-toimija esitellään.
Unsure about a term? See the cold chain glossary (CAPEX, OPEX, blast freezing).
Keskustele ColdMatchin hankinta-asiantuntijan kanssa
Lähetämme laskurin tiedot ColdMatchin asiantuntijalle, joka tarkistaa projektin ennen mahdollisen toimittajahaun aloittamista. Ei sitoumuksia.
Send these inputs to an RFQ
Your size, cost and load inputs are copied into the quote form, so you don't type them twice. Nothing is sent until you review and submit.
Lähetä hankkeesi asiantuntijan arvioitavaksi
Lähetä vaatimuksesi. ColdMatchin asiantuntija käy jokaisen pyynnön läpi, laatii tiivistelmän ja esittelee päteviä toimittajia — maksutta pätevöityneille ostajille.