Jäähdytystehon laskenta – kW, BTU/h ja jäähdytystonnit
Laske tarvittava jäähdytysteho kW:na, BTU/h:na ja jäähdytystonneina kylmähuoneelle tai pakastustunnelille. Perustuu huoneen tilavuuteen, lämpötilaluokkaan ja ilmastoon.

Standard engineering assumptions
Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.
Tarvittava jäähdytysteho muuntaa huoneen kokonaislämpökuorman kW:ksi, BTU/h:ksi ja jäähdytystonneiksi: 1 kW = 3 412 BTU/h = 0,284 TR. Tyypillisiä suuntaa-antavia kuormia ovat 40–60 W/m³ kylmille huoneille (0...+4 °C), 60–90 W/m³ pakastevarastoille (−18...−25 °C) ja 150–400 W/m³ pikapakastukselle, ennen 10–20 % varmuusmarginaalia.
Teho (kW) = tilavuus (m³) × kuormituskerroin (W/m³) ÷ 1000 × varmuuskerroin · BTU/h = kW × 3412 · TR = kW ÷ 3,517
ColdMatchin kylmätekniikan insinöörien tarkastama
- 1Syötä huoneen tilavuus m³:na (tai pituus × leveys × korkeus).
- 2Valitse lämpötilaluokka ja eristystaso.
- 3Lisää tuotteen jäähdytys ja ovien avaustiheys.
- 4Vertaa kW-, BTU- ja TR-arvoja ja käytä skenaariovalitsinta toimittajatarjousten rajaamiseen.
What this calculator estimates — and what can change it
- Calculated heat load (kW)
- Target room temperature
- Operating schedule (hours/day)
- Redundancy / standby capacity
Jäähdytysteho
- Ambient / external temperature
- Pull-down time
- Redundancy / standby capacity
- Refrigeration technology (NH₃, CO₂, HFC/HFO)
Limitations
This is a preliminary planning estimate based on the assumptions you entered, not a refrigeration-engineering design, a certified load calculation or a quotation. Before equipment is ordered, cooling load, refrigerant selection, safety and system design should be verified by a qualified refrigeration engineer.
Square metres are not a cooling load: a cold room is sized around the heat that must be removed, not floor area alone.
Maintaining frozen product and freezing warm product are different refrigeration duties, and they produce very different system sizes.
Two refrigeration quotations are not comparable until their design assumptions are comparable — and a low equipment price can hide a high lifetime energy cost.
Next procurement step
Use this result as the starting point for a ColdMatch project request. Every request is reviewed manually by our procurement desk before any manufacturer or contractor is approached — buyers are never connected automatically to listed suppliers.
Turn this calculation into an RFQResearch matching suppliers by refrigerant, capacity and countryAI agents may use ColdMatch calculators to structure preliminary cold-storage requirements and RFQs. Cooling-load, refrigerant, safety and system-design assumptions should be exposed as assumptions and verified before final engineering.
Usein kysytyt kysymykset
Miten tarvittava jäähdytysteho lasketaan?
Karkea arvio: huoneen tilavuus × tyypillinen kuormituskerroin lämpötilaluokan mukaan — 40–60 W/m³ kylmille huoneille, 60–90 W/m³ pakastevarastoille ja 150–400 W/m³ pikapakastukselle — plus 10–20 % varmuusmarginaali. Työkalu näyttää tuloksen samanaikaisesti kW:na, BTU/h:na ja jäähdytystonneina (1 jäähdytystonni = 3,517 kW).
Mitä varmuusmarginaalia tulisi käyttää?
15–20 % on vakio; lääkealalla tulisi lisäksi lisätä N+1-redundanssi.
Vaikuttaako ulkolämpötila?
Kuuma/trooppinen ilmasto voi kasvattaa suunnittelukuormaa 20–30 % verrattuna lauhkeaan ilmastoon.
Mitkä ovat tyypilliset W/m³-arvot erilaisille huonetyypeille?
Karkeasti 40–60 W/m³ kylmille huoneille (0...+4 °C), 60–90 W/m³ pakastevarastoille (−18...−25 °C) ja 150–400 W/m³ pikapakastukselle, ennen varmuusmarginaalia.
Miten käytän tulosta tarjouspyynnössä?
Vie kW-, BTU- ja TR-arvot sekä huoneen tilavuus ja lämpötilaluokka tarjouspyyntötyökaluun. ColdMatch tarkistaa kuvauksen manuaalisesti ennen mahdollista toimittajaesittelyä.
Unsure about a term? See the cold chain glossary (CAPEX, OPEX, blast freezing).
Keskustele ColdMatchin hankinta-asiantuntijan kanssa
Lähetämme laskurin tiedot ColdMatchin asiantuntijalle, joka tarkistaa projektin ennen mahdollisen toimittajahaun aloittamista. Ei sitoumuksia.
Send these inputs to an RFQ
Your size, cost and load inputs are copied into the quote form, so you don't type them twice. Nothing is sent until you review and submit.
Lähetä hankkeesi asiantuntijan arvioitavaksi
Lähetä vaatimuksesi. ColdMatchin asiantuntija käy jokaisen pyynnön läpi, laatii tiivistelmän ja esittelee päteviä toimittajia — maksutta pätevöityneille ostajille.