Not sure which tool fits? Open smart search — every question mapped to the right calculator
Kompressorin mitoitus kylmälaitoksille
Arvioi moottoriteho, COP ja iskutilavuus kompressoreille, jotka käyttävät NH₃:a, transkriittistä CO₂:a, HFO-seoksia ja propaania.

Standard engineering assumptions
Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.
Kompressorin mitoitus perustuu höyrystimen tehoon kW:na ja käytön COP-arvoon: akseliteho ≈ jäähdytysteho ÷ COP. Tyypillinen COP on 3,5–5,0 kylmäkäytössä (−5 °C höyrystyminen) ja 1,4–2,2 pakastekäytössä (−35 °C). Ammoniakki (NH₃) antaa yleensä parhaan hyötysuhteen suurissa laitoksissa, kun taas CO₂ (R-744) sopii pienen täyttömäärän järjestelmiin ja kaskadijärjestelmiin.
Moottoriteho (kW) = jäähdytysteho (kW) ÷ COP ÷ moottorin hyötysuhde · Iskutilavuus (m³/h) = massavirta × imupuolen ominaistilavuus
ColdMatchin kylmätekniikan insinöörien tarkastama
- 1Syötä tarvittava jäähdytysteho kW:na kuormalaskelmastasi.
- 2Valitse kylmäaine (NH₃, CO₂, R-448A/449A, propaani) ja höyrystymislämpötila.
- 3Aseta lauhtumislämpötila sijainnin ilmaston mukaan.
- 4Vertaa akselitehoa, COP:ia ja iskutilavuutta, ja pyydä yhteensopivia kompressoripaketteja.
What this calculator estimates — and what can change it
- Calculated heat load (kW)
- Target room temperature
- Ambient / external temperature
- Refrigeration technology (NH₃, CO₂, HFC/HFO)
- Redundancy / standby capacity
Kompressorin mitoitus
- Refrigeration technology (NH₃, CO₂, HFC/HFO)
- Ambient / external temperature
- Redundancy / standby capacity
- Pull-down time
Limitations
This is a preliminary planning estimate based on the assumptions you entered, not a refrigeration-engineering design, a certified load calculation or a quotation. Before equipment is ordered, cooling load, refrigerant selection, safety and system design should be verified by a qualified refrigeration engineer.
Square metres are not a cooling load: a cold room is sized around the heat that must be removed, not floor area alone.
Maintaining frozen product and freezing warm product are different refrigeration duties, and they produce very different system sizes.
Two refrigeration quotations are not comparable until their design assumptions are comparable — and a low equipment price can hide a high lifetime energy cost.
Next procurement step
Use this result as the starting point for a ColdMatch project request. Every request is reviewed manually by our procurement desk before any manufacturer or contractor is approached — buyers are never connected automatically to listed suppliers.
Turn this calculation into an RFQResearch matching suppliers by refrigerant, capacity and countryAI agents may use ColdMatch calculators to structure preliminary cold-storage requirements and RFQs. Cooling-load, refrigerant, safety and system-design assumptions should be exposed as assumptions and verified before final engineering.
Usein kysytyt kysymykset
Miten kylmäkompressori mitoitetaan?
Höyrystymislämpötilan (Te), lauhtumislämpötilan (Tc), kylmäaineen ominaisuuksien ja tarvittavan jäähdytystehon perusteella — näistä saadaan moottoriteho ja iskutilavuus.
Mikä on odotettu COP?
Kylmätila: 3,5–5,0. Pakastetila: 1,4–2,2. Pikapakastus: alhaisemmat arvot.
Ruuvi- vai mäntäkompressori?
Alle 50 kW: mäntä/scroll. 50–500 kW: ruuvi. Yli 500 kW: ruuvi tai keskipakokompressori.
Mikä kylmäaine antaa parhaan hyötysuhteen?
Ammoniakki (NH₃) antaa yleensä parhaan hyötysuhteen suurissa laitoksissa, kun taas CO₂ (R-744) sopii pienen täyttömäärän järjestelmiin ja kaskadijärjestelmiin.
Miten käytän lukuja tarjouspyynnössä?
Vie jäähdytysteho, Te, Tc ja valittu kylmäaine tarjouspyyntötyökaluun, jotta toimittajat voivat tarjota yhteensopivia kompressoripaketteja. ColdMatch tarkistaa kuvauksen manuaalisesti ennen mahdollista toimittajaesittelyä.
Unsure about a term? See the cold chain glossary (CAPEX, OPEX, blast freezing).
Keskustele ColdMatchin hankinta-asiantuntijan kanssa
Lähetämme laskurin tiedot ColdMatchin asiantuntijalle, joka tarkistaa projektin ennen mahdollisen toimittajahaun aloittamista. Ei sitoumuksia.
Send these inputs to an RFQ
Your size, cost and load inputs are copied into the quote form, so you don't type them twice. Nothing is sent until you review and submit.
Lähetä hankkeesi asiantuntijan arvioitavaksi
Lähetä vaatimuksesi. ColdMatchin asiantuntija käy jokaisen pyynnön läpi, laatii tiivistelmän ja esittelee päteviä toimittajia — maksutta pätevöityneille ostajille.