Kyllastberäkning – transmission, produkt och infiltration
Fullständig nedbrytning av värmelast i kW — klimatskal, nedkylning av produkt, infiltration och övriga interna tillskott för kylrum och frysrum.

Standard engineering assumptions
Kyl-kW är värme som avlägsnas från rummet — inte elektrisk kW. Elförbrukning ≈ kyllast ÷ system-COP, plus hjälpförbrukning.
Endast en planeringsberäkning. Slutlig kapacitet, utrustningsval, köldmedium, säkerhetskrav, pris och energiprestanda måste bekräftas av den valda kvalificerade kylleverantören.
Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.
Total kyllast är summan av fyra komponenter: transmission genom klimatskalet, nedkylning av produkt, luftinfiltration genom dörrar samt interna tillskott från fläktar, belysning, truckar och personer. I ett typiskt kyllager utgör transmission 25–40 %, produkt 20–45 %, infiltration 15–30 % och interna tillskott 10–20 % av totalen.
Q total = Q transmission + Q produkt + Q infiltration + Q internt · Q transmission = U × A × ΔT
Granskad av ColdMatchs kylteknikingenjörer
- 1Ange rumsdimensioner, paneltjocklek och utetemperatur för design.
- 2Lägg till dagligt produktintag och dess ingångstemperatur.
- 3Ange antal dörröppningar per dag och intern utrustningslast.
- 4Granska fördelningen per komponent och använd total kW i val av utrustning.
Relaterade kalkylatorer
What this calculator estimates — and what can change it
- Room dimensions
- Stored product
- Incoming product temperature
- Target room temperature
- Daily throughput (t/day)
- Door openings per day
Kyllast
- Freezing duty (latent heat)
- Incoming product temperature
- Humidity target
- Door openings per day
- Panel insulation thickness
Limitations
This is a preliminary planning estimate based on the assumptions you entered, not a refrigeration-engineering design, a certified load calculation or a quotation. Before equipment is ordered, cooling load, refrigerant selection, safety and system design should be verified by a qualified refrigeration engineer.
Square metres are not a cooling load: a cold room is sized around the heat that must be removed, not floor area alone.
Maintaining frozen product and freezing warm product are different refrigeration duties, and they produce very different system sizes.
Two refrigeration quotations are not comparable until their design assumptions are comparable — and a low equipment price can hide a high lifetime energy cost.
Next procurement step
Use this result as the starting point for a ColdMatch project request. Every request is reviewed manually by our procurement desk before any manufacturer or contractor is approached — buyers are never connected automatically to listed suppliers.
Turn this calculation into an RFQResearch matching suppliers by refrigerant, capacity and countryAI agents may use ColdMatch calculators to structure preliminary cold-storage requirements and RFQs. Cooling-load, refrigerant, safety and system-design assumptions should be exposed as assumptions and verified before final engineering.
Vanliga frågor
Hur beräknar man kyllast för ett kylrum?
Kyllasten är summan av fyra led: transmission genom klimatskalet (U × A × ΔT), nedkylning av inkommande produkt, infiltration genom dörrar samt interna tillskott från belysning, fläktar, truckar och personal. Kalkylatorn visar varje led separat i kW och summerar dem till total kyllast.
Vilket U-värde bör panelerna ha?
Kylt 0,25–0,35, fryst 0,18–0,22, snabbfrysning 0,15 W/m²K eller bättre.
Hur mycket ökar dörröppningar lasten?
I livliga distributionscentraler kan infiltration utgöra 15–25 % av den totala lasten.
Hur fördelar sig de fyra komponenterna vanligtvis?
I ett typiskt kyllager är transmission 25–40 %, produkt 20–45 %, infiltration 15–30 % och interna tillskott 10–20 % av totalen.
Hur omvandlar jag resultatet till en förfrågan om anläggning?
Ta med totalt kW-värde och fördelningen per komponent i RFQ-verktyget tillsammans med rumsförhållanden. ColdMatch granskar briefen manuellt innan någon leverantör eller EPC-aktör introduceras.
Unsure about a term? See the cold chain glossary (CAPEX, OPEX, blast freezing).
Prata med en ColdMatch-inköpsrådgivare
Vi skickar dina kalkylatoruppgifter till en ColdMatch-specialist, som granskar projektet innan eventuell leverantörssökning påbörjas. Inga förpliktelser.
Send these inputs to an RFQ
Your size, cost and load inputs are copied into the quote form, so you don't type them twice. Nothing is sent until you review and submit.
Submit your project for expert review
Send your requirements. A ColdMatch specialist reviews every request, prepares a brief and introduces qualified suppliers — free for qualified buyers.