Kuldelastberegning – transmisjon, produkt og infiltrasjon
Full nedbryting av varmelast i kW — klimaskall, nedkjøling av produkt, infiltrasjon og øvrige interne tilskudd for kjølerom og fryserom.

Standard engineering assumptions
Kulde-kW er varme fjernet fra rommet — ikke elektrisk kW. Elektrisk forbruk ≈ kuldelast ÷ system-COP, pluss hjelpeforbruk.
Kun planleggingsberegning. Endelig kapasitet, utstyrsvalg, kuldemedium, sikkerhetskrav, pris og energiytelse må bekreftes av den valgte, kvalifiserte kuldeleverandøren.
Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.
Total kuldelast er summen av fire komponenter: transmisjon gjennom klimaskallet, nedkjøling av produkt, luftinfiltrasjon gjennom dører, samt interne tilskudd fra vifter, lys, gaffeltrucker og personer. I et typisk kjølelager utgjør transmisjon 25–40 %, produkt 20–45 %, infiltrasjon 15–30 % og interne tilskudd 10–20 % av totalen.
Q total = Q transmisjon + Q produkt + Q infiltrasjon + Q internt · Q transmisjon = U × A × ΔT
Gjennomgått av ColdMatchs kuldeteknikk-ingeniører
- 1Skriv inn romdimensjoner, panteltykkelse og utetemperatur for design.
- 2Legg til daglig produktinntak og dets inngangstemperatur.
- 3Angi antall døråpninger per dag og internt utstyrsforbruk.
- 4Se gjennom fordelingen per komponent og bruk total kW i valg av utstyr.
What this calculator estimates — and what can change it
- Room dimensions
- Stored product
- Incoming product temperature
- Target room temperature
- Daily throughput (t/day)
- Door openings per day
Kuldelast
- Freezing duty (latent heat)
- Incoming product temperature
- Humidity target
- Door openings per day
- Panel insulation thickness
Limitations
This is a preliminary planning estimate based on the assumptions you entered, not a refrigeration-engineering design, a certified load calculation or a quotation. Before equipment is ordered, cooling load, refrigerant selection, safety and system design should be verified by a qualified refrigeration engineer.
Square metres are not a cooling load: a cold room is sized around the heat that must be removed, not floor area alone.
Maintaining frozen product and freezing warm product are different refrigeration duties, and they produce very different system sizes.
Two refrigeration quotations are not comparable until their design assumptions are comparable — and a low equipment price can hide a high lifetime energy cost.
Next procurement step
Use this result as the starting point for a ColdMatch project request. Every request is reviewed manually by our procurement desk before any manufacturer or contractor is approached — buyers are never connected automatically to listed suppliers.
Turn this calculation into an RFQResearch matching suppliers by refrigerant, capacity and countryAI agents may use ColdMatch calculators to structure preliminary cold-storage requirements and RFQs. Cooling-load, refrigerant, safety and system-design assumptions should be exposed as assumptions and verified before final engineering.
Ofte stilte spørsmål
Hvordan beregner jeg kuldelast for et kjølerom?
Kuldelasten er summen av fire ledd: transmisjon gjennom klimaskallet (U × A × ΔT), nedkjøling av produkt ved inngang, infiltrasjon gjennom dører og interne tilskudd fra belysning, vifter, trucker og personell. Kalkulatoren viser hvert ledd for seg i kW og summerer dem til total kuldelast.
Hvilken U-verdi bør panelene ha?
Kjølt 0,25–0,35, fryst 0,18–0,22, spesialfrysing 0,15 W/m²K eller bedre.
Hvor mye øker dørbruk lasten?
I travle distribusjonssentre kan infiltrasjon utgjøre 15–25 % av total last.
Hvordan fordeler de fire komponentene seg typisk?
I et vanlig kjølelager er transmisjon 25–40 %, produkt 20–45 %, infiltrasjon 15–30 % og interne tilskudd 10–20 % av totalen.
Hvordan omsetter jeg resultatet til en forespørsel om anlegg?
Ta total kW-verdi og fordelingen per komponent inn i RFQ-verktøyet sammen med romforhold. ColdMatch gjennomgår notatet manuelt før noen leverandør eller EPC-aktør introduseres.
Unsure about a term? See the cold chain glossary (CAPEX, OPEX, blast freezing).
Snakk med en ColdMatch innkjøpsrådgiver
Vi sender kalkulatordataene dine til en ColdMatch-spesialist, som gjennomgår prosjektet før eventuelt leverandørsøk starter. Ingen forpliktelse.
Send these inputs to an RFQ
Your size, cost and load inputs are copied into the quote form, so you don't type them twice. Nothing is sent until you review and submit.
Submit your project for expert review
Send your requirements. A ColdMatch specialist reviews every request, prepares a brief and introduces qualified suppliers — free for qualified buyers.