Offline — reconnect before saving or submitting. Changes on this page have not been sent.

Pharmaceutical RFQ · GDP scope

Pharmaceutical cold storage RFQ: temperature bands, validation scope and project brief

Direct answer: a pharmaceutical cold storage RFQ is comparable only when every bidder prices the same written basis — temperature bands and tolerance, facility type, net volume or pallet positions, design ambient, redundancy level, monitoring and alarms, validation scope (IQ/OQ/PQ and mapping) and handover date. This short step-by-step brief collects exactly those, with your drawings and URS. A person at ColdMatch then reviews it; no supplier is approached automatically.

Start the RFQ
  • +15/+25 °C to -80 °C bands
  • IQ/OQ/PQ & mapping scope
  • Attach URS, drawings, audits

Build your pharmaceutical RFQ

Short steps, mostly taps. Around three minutes.

ColdMatch facilitates sourcing and RFQs; it does not manufacture, sell, import or export the listed products and is not a regulatory authority. Suppliers are responsible for their products meeting the requirements of the origin and destination countries; buyers for import permissions, local rules and due diligence. Requirements vary by product and country, and the team checks requests before any supplier contact. Regulation and restricted items

Which temperatures and facility?

Temperature bands required
Facility type

Free for buyers. Documents are shared only by the ColdMatch team, with suppliers relevant to your project.

We use the details you enter to handle this request and follow up on it. Buyer contact details are shared with a supplier only through a ColdMatch introduction. How long we keep data and your rights: Privacy Policy

Technical reference

Pharmaceutical cold storage: bands, loads and validation scope

Planning references used to write a comparable RFQ. Specific duty figures are per m³ of net room volume at a 32–40 °C design ambient and vary with door traffic, insulation and product throughput. The applicable storage condition for your product comes from its marketing authorisation, not from this table.

Temperature bands, envelope and typical specific refrigeration duty
BandTypical useEnvelope U-valueSpecific dutyRedundancyValidation
+15 / +25 °CControlled room temperature — general stock0.24 W/m²K (100 mm PIR)8–14 W/m³N, alarmedMapping + PQ
+2 / +8 °CVaccines, biologics, insulin0.20 W/m²K (120 mm PIR)18–28 W/m³N+1 typicalIQ/OQ/PQ + mapping
−20 °CFrozen API, plasma, bulk intermediates0.16 W/m²K (150 mm PIR)35–50 W/m³N+1, gensetIQ/OQ/PQ + mapping
−70 / −80 °CmRNA vaccines, cell & gene, clinical samples0.11 W/m²K (200 mm+)90–140 W/m³2N commonIQ/OQ/PQ, LN2 backup
Where the refrigeration duty comes from
Load componentDriverShare of dutyDesign lever
TransmissionEnvelope area × U-value × (ambient − room)35–55%Panel thickness, shaded plant location, warm-side vapour barrier
InfiltrationDoor openings, door type, airlock, ΔT10–30%Airlock or rapid-roll door, dock shelters, picking discipline
Product pull-downDaily intake × specific heat × ΔT (+ latent if freezing)10–25%Pre-cooled receipts, staged intake, dedicated pull-down room
Internal gainsFans, lighting, defrost, people, monitoring, UPS8–15%EC fans, LED with occupancy control, demand defrost
Safety marginDesign uncertainty, fouling, future load10–15%Agree the margin in the RFQ so bids are comparable
Validation and monitoring scope to state before suppliers quote
Scope itemWhat it coversWho owns itState in the RFQ
Temperature mappingLoaded, empty and worst-case (door-open, power-loss) studies with calibrated loggers over 72+ hoursSupplier or validation houseState logger count, duration and scenarios
IQ / OQ / PQInstallation, operational and performance qualification against an approved URSSupplier, approved by your QASay who writes and who approves each protocol
Monitoring & alarmingCalibrated probes, logging interval, tiered escalation, off-site backup, data retentionSupplier / integratorGive interval, retention period and escalation times
Redundancy & standby powerN+1 or 2N refrigeration, generator start time, UPS on controls and monitoringOperator decision, supplier deliveryState the level — not a supplier assumption
RequalificationPeriodic remapping and protocol review, typically annualOperatorInclude first-year support in scope

Size your own room against these figures in the pharma cold storage capacity planner, then carry the result into the pharmaceutical RFQ. Every request is read by a person before any supplier is approached.

The pharma RFQ path: from temperature band to comparable bids

Every pharmaceutical cold chain page on ColdMatch leads to the same qualification path. Figures used along the way are planning bands from comparable projects — never quotations, never contractor recommendations.

  1. Step 1

    Fix the design basis

    Temperature bands and tolerance, product type, net volume or pallet positions, design ambient, monitoring level and redundancy. Without these, bids cannot be compared.

    Pharma cold room calculator →
  2. Step 2

    Check whether the project is ready

    The readiness check shows in a few minutes which parts of the basis are still missing and which exclusions bidders will price differently.

    RFQ readiness check →
  3. Step 3

    Write one comparable brief

    One written scope, one exclusion sheet, one validation scope (IQ/OQ/PQ and temperature mapping) — so every bidder prices the same project.

    Pharmaceutical cold storage RFQ →
  4. Step 4

    Human review, then supplier search

    ColdMatch reads the brief, comes back on what is missing and only then researches suppliers. Projects are generally reviewed from about USD 250,000 expected value. No supplier is approached without your approval.

    How ColdMatch works →

Start from your scope

Plan by market

Pharmaceutical RFQ questions

What should a pharmaceutical cold storage RFQ include?+

Temperature bands and tolerance, facility type, net storage volume or pallet positions, ambient design conditions, redundancy level, validation scope (IQ/OQ/PQ, mapping), monitoring and alarm requirements, backup power, and the required handover date. This form collects each of those so suppliers quote on identical scope.

Can I attach drawings, URS or validation documents?+

Yes. You can upload up to 6 files (10 MB each) — layout drawings, user requirement specifications, temperature mapping reports, tender documents or audit findings. Documents stay internal; nothing is sent outside ColdMatch before you approve it.

What happens after I send the request?+

A person reads it. ColdMatch reviews the scope, comes back on what is still missing (design ambient, redundancy level, validation scope), and only then structures the supplier search. There is no automatic buyer-supplier connection and no supplier is contacted without your approval.

Why do pharma cold storage bids differ so much?+

Almost always the exclusion list, not the unit rate: HV coordination and standby power, machine-room gas detection, commissioning attendance, spare parts, and DQ/IQ/OQ/PQ qualification with temperature mapping. Requiring one common exclusion sheet is what makes bids readable.

Which temperature band should I specify?+

The band comes from the product specification, the manufacturer's storage instructions and the regulations of the destination market — not from a general rule. Typical bands in use are +15/+25 °C CRT, +2/+8 °C, −20 °C, −70/−80 °C and cryogenic below −150 °C.

What project sizes does ColdMatch review?+

Commercial and industrial pharmaceutical cold storage projects, generally from about USD 250,000 expected value — from a single validated +2/+8 °C room to multi-zone GDP distribution centres.

Related pharmaceutical resources