Soğuk Depo Elektrik Maliyeti Hesaplama
Soğuk deponun yıllık elektrik giderini USD cinsinden modelleyin; kWh tüketimini ve talep / kapasite bedellerini ayrı ayrı görün.

Standard engineering assumptions
Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.
Soğuk deponun yıllık elektrik maliyeti, ortalama elektrik yükü × çalışma saatleri × tarife hesabına talep (kVA) bedellerinin eklenmesiyle bulunur. Soğutma genellikle soğuk deponun elektrik faturasının 60–70 % bölümünü oluşturur. İyi işletilen bir tesis, soğuk muhafazada yılda m³ başına yaklaşık 30–55 kWh, donmuş muhafazada ise 55–95 kWh/m³/yıl tüketir.
Annual cost = kW × hours/year × load factor × tariff (USD/kWh) + peak kW × demand charge × 12
ColdMatch soğutma mühendisleri tarafından incelendi
- 1Tesisin elektrik yükünü kW cinsinden ve çalışma saatlerini girin.
- 2USD/kWh cinsinden tarifenizi ve varsa talep veya puant ek bedelini ekleyin.
- 3Mevsimsel yükü yansıtan yük faktörünü uygulayın.
- 4Yıllık kWh tüketimini ve maliyeti inceleyin, ardından senaryo seçiciyle tasarrufları test edin.
İlgili hesaplama araçları
What this calculator estimates — and what can change it
- Calculated heat load (kW)
- System efficiency (COP / SEPR)
- Operating schedule (hours/day)
- Electricity tariff
- Project country
Elektrik maliyeti
- Electricity tariff
- System efficiency (COP / SEPR)
- Ambient / external temperature
- Operating schedule (hours/day)
Limitations
This is a preliminary planning estimate based on the assumptions you entered, not a refrigeration-engineering design, a certified load calculation or a quotation. Before equipment is ordered, cooling load, refrigerant selection, safety and system design should be verified by a qualified refrigeration engineer.
Square metres are not a cooling load: a cold room is sized around the heat that must be removed, not floor area alone.
Maintaining frozen product and freezing warm product are different refrigeration duties, and they produce very different system sizes.
Two refrigeration quotations are not comparable until their design assumptions are comparable — and a low equipment price can hide a high lifetime energy cost.
Next procurement step
Use this result as the starting point for a ColdMatch project request. Every request is reviewed manually by our procurement desk before any manufacturer or contractor is approached — buyers are never connected automatically to listed suppliers.
Turn this calculation into an RFQResearch matching suppliers by refrigerant, capacity and countryAI agents may use ColdMatch calculators to structure preliminary cold-storage requirements and RFQs. Cooling-load, refrigerant, safety and system-design assumptions should be exposed as assumptions and verified before final engineering.
Sıkça Sorulan Sorular
Yük faktörü ne olmalı?
45–65% tipiktir; şok dondurucularda 40% düzeyine düşebilir.
Akıllı kontrol sistemleri ne kadar tasarruf sağlar?
EC fanlar, değişken yoğuşma basıncı kontrolü ve uyarlamalı defrost, kWh tüketimini 15–25% azaltır.
Talep bedellerinin etkisi nedir?
kVA/kW tarifelerinde yalnızca kWh tüketimine dayalı maliyete 20–35% ekler.
Yıllık elektrik maliyeti nasıl hesaplanır?
Yıllık tüketim = soğutma yükü ÷ COP × çalışma saatleri × yük faktörü; yıllık maliyet = bu tüketim × tarifeniz, ayrıca sözleşmenizde varsa talep veya kapasite bedelleri. Düşük kWh fiyatının yüksek talep bedelini gizlememesi için enerji ve güç bedelleri ayrı gösterilir.
Hangi tarifeyi girmeliyim?
İlan edilen birim fiyatı değil, geçen yılki gerçek faturalarınızdan hesapladığınız, fiilen ödediğiniz ortalama kWh maliyetini kullanın. Elektrik şirketiniz kVA veya kW üzerinden sözleşme gücü bedeli alıyorsa bunu da ekleyin. kVA/kW tarifelerinde talep bedelleri, yalnızca tüketim maliyetinin üzerine genellikle 20–35% ekler.
Sonucu gerçek faturalarımla nasıl karşılaştırırım?
Geçen yılın toplam kWh tüketimini soğuk depo hacminize bölün: endüstriyel donmuş depolar genellikle yılda m³ başına 60–100 kWh, soğuk muhafaza odaları ise 25–40 tüketir. Gerçek tüketiminiz bu aralığın çok dışındaysa modeldeki COP veya çalışma saatleri yanlıştır. Enerji tasarrufu hesaplama aracı bu farkı kapatmak için tasarlanmıştır.
İki soğutma seçeneğini bununla karşılaştırabilir miyim?
Evet. Her seçenek için kendi COP değeri ve yük profiliyle ayrı hesaplama yapın; ardından her iki yıllık değeri ilgili yatırım harcamasıyla birlikte yatırım getirisi hesaplama aracına girin. Böylece kWh farkı geri ödeme süresi farkına dönüşür; tedarikçiler bu şekilde karşılaştırılmalıdır.
Unsure about a term? See the cold chain glossary (CAPEX, OPEX, blast freezing).
ColdMatch tedarik danışmanıyla görüşün
Hesaplama girdilerinizi bir ColdMatch tedarik uzmanına ileteceğiz. Uzmanımız, tedarikçi araştırması başlamadan önce projenizi inceler. Hiçbir yükümlülük yoktur.
Send these inputs to an RFQ
Your size, cost and load inputs are copied into the quote form, so you don't type them twice. Nothing is sent until you review and submit.
Submit your project for expert review
Send your requirements. A ColdMatch specialist reviews every request, prepares a brief and introduces qualified suppliers — free for qualified buyers.