← Volver al Centro de Conocimiento
Industry guide

Distribución 3PL Congelada — Guía de Diseño de CDs Multi-Temperatura

Diseña CDs multi-temperatura para QSR, retail y 3PL: zonas ambiente / +2 °C / −18 °C / −25 °C, opciones ASRS y estrategia energética.

Zone strategy

Cluster same-temperature SKUs in single zones with dedicated docks. Use insulated dock seals between zones. Multi-temp docks with air curtains work but energy-penalty is 15–25% vs discrete docks.

ASRS vs conventional

ASRS high-bay (25–35 m) triples pallet density and cuts labour cost per pallet by 55–65%. Payback typically 5–8 years at labour cost >€25/hr. Below that, conventional VNA or wide-aisle wins.

Refrigeration

CO₂ transcritical is now standard for new frozen DCs in temperate climates; below 32 °C ambient, transcritical parallel compression matches NH₃/CO₂ cascade on efficiency. Above 40 °C ambient, NH₃/CO₂ cascade still wins.

Energy strategy

Combine PV (roof or car-park canopy) with ice-bank thermal storage for peak-shaving. Heat recovery to office/dock heating covers 100% of winter heat demand. Target ≤28 kWh/pallet·yr in temperate, ≤38 in hot climates.

Preguntas frecuentes

When does ASRS actually pay back?

When labour cost exceeds €25/hr and pallet throughput exceeds 15,000/week. Below that, conventional VNA with lithium forklifts wins on capex flexibility.

How many docks per 10,000 m² of frozen DC?

Rule of thumb: 1 dock per 400–500 m² of frozen storage for retail replenishment DCs; 1 per 300 m² for QSR (higher turn). Add 30% peak overhead.

RFQ from this guide

Solicita cotizaciones de proveedores gratis

Envía una RFQ y recibe cotizaciones preseleccionadas de EPCs de refrigeración verificados.

Industry
logistics
Temperature
−25 °C bulk / +2/+8 °C chill
Budget
€10M – €80M
Timeline
14–24 months
Equipment
Multi-temperature 3PL warehouse, ASRS optional, dock chillers
Solicita cotizaciones de proveedores gratis

Opens the RFQ builder with fields prefilled from this guide — editable before submission.

Get QuotesTalk to Expert