Offline — reconnect before saving or submitting. Changes on this page have not been sent.

Industrial refrigeration projects — engineering, delivery and financing
Industrial Refrigeration Projects

Industrial refrigeration projects — engineering, delivery and financing

ColdMatch sources industrial refrigeration projects worldwide: ammonia and CO₂ plants, IQF tunnels, process cooling, blast freezers and full plant refits. Independent, EPC-agnostic and financing-ready.

Human Global Expert Guidance•Vendor-Neutral Procurement•Team-Led Supplier Outreach•Commercial Confidentiality
Talk to a cold-chain expert on WhatsApp

What ColdMatch delivers

  • NH₃, CO₂, cascade and low-charge refrigeration plants
  • Process cooling for food, dairy, beverage, meat and seafood plants
  • Blast freezing, IQF and hardening tunnels
  • Retrofit, plant upgrade and refrigerant conversion projects
  • Financing for plant, installation and commissioning
How matching works

You submit one RFQ. Our team handles the supplier outreach.

There is no direct buyer-to-supplier connection. Your request comes to the ColdMatch team, which contacts suitable suppliers and manufacturers on your behalf. Supplier and manufacturer information on this site is for research only; it is not a contact directory and does not mean a supplier has been vetted.

  1. You build your project and submit an RFQ.
  2. The ColdMatch team validates and organizes the requirements.
  3. We contact suitable suppliers and manufacturers for you.
  4. We present their organized responses to you through ColdMatch.

Supplier and manufacturer information is provided for research only; it is not a directory for direct contact. There is no direct buyer-to-supplier connection: every RFQ comes to the ColdMatch team, which validates it, contacts suitable suppliers on the buyer's behalf and presents organized responses through ColdMatch.

Buyer briefing — industrial refrigeration projects

What are the stages of an industrial refrigeration project?

Load survey and duty definition, concept design and refrigerant selection, budget and business case, tender and supplier comparison, detailed engineering, manufacture and delivery, mechanical and electrical installation, pressure testing and charging, commissioning under load, operator training and handover. Weak load definition at stage one is the single most common cause of re-pricing later.

How is refrigeration load calculated for a project?

Total load combines transmission through walls, roof and floor, product pull-down and respiration heat, air infiltration through doors and dock openings, fan, defrost, lighting and personnel loads, plus a design margin. Frozen duty, high door traffic and hot-humid ambients push installed capacity well above the naive volume-based estimate, which is why comparable quotes require throughput data, not just m³.

When should ammonia, CO2 or an HFO system be considered?

Ammonia suits large single-site industrial loads above roughly 300 kW where a machinery room, trained operators and safety compliance are viable — it delivers the best efficiency per kW installed. Transcritical CO2 suits mid-size and cooler-climate sites and locations where ammonia is restricted; performance improves with parallel compression or ejectors in hot climates. HFO or blended synthetic systems suit smaller, distributed or unattended plant where an operator regime is not practical.

What redundancy should an industrial plant have?

Match redundancy to the cost of a loss event. Multi-compressor plant with N+1 capacity, dual condenser circuits, dual refrigerant paths on critical rooms, generator-backed control and alarm systems, and mapped restart procedures. For pharmaceutical and high-value frozen inventory, backup generation for the full refrigeration load is normal; for short-dwell chilled goods, thermal inertia may cover a short outage.

Typical project scale
  • •150–500 kW packaged plant for a processing line
  • •500 kW–2 MW central plant serving multiple temperature zones
  • •2 MW+ multi-stage plant with heat recovery
  • •Plant replacement or refrigerant conversion on a live site

Exact system sizing depends on required temperature, ambient climate, product load and turnover rate, door openings, insulation specification, storage duration, redundancy level and operating hours. ColdMatch does not manufacture equipment — we help industrial buyers compare suitable suppliers and technologies against project-specific technical and commercial requirements.

Information suppliers need to quote
  • •Country, project location and site status (greenfield or existing building)
  • •Application and product stored or processed
  • •Required temperature range and any humidity requirement
  • •Storage capacity (m², m³ or pallet positions) and daily throughput
  • •Ambient/design climate conditions at site
  • •Available power supply and backup or redundancy requirement
  • •Preferred refrigerant, if already defined by policy or regulation
  • •Indicative budget range and target commissioning date
  • •Duty per temperature level and peak simultaneous load
  • •Existing plant to be retained, replaced or run in parallel
  • •Machinery room availability and operator competence on site
  • •Acceptable shutdown window for tie-in and commissioning
Request Refrigeration Plant Quotes
Continue your specification

Frequently asked questions

How ColdMatch Group works — independent B2B procurement and sourcing platform — ColdMatch Group is an independent B2B procurement and sourcing platform for industrial refrigeration, cold storage and cold-chain projects from USD $250K+, where the ColdMatch team reviews each buyer brief, contacts suitable third-party suppliers on the buyer's behalf and organizes their responses.

Buyer Guides Hub

Explore every ColdMatch buying guide

RFQ checklist, cost benchmarks, and country-by-country buying guides — all in one hub.

Back to Guides Hub
Qualify, then request quotes

Take this to a structured refrigeration RFQ

Refrigeration bids are only comparable when refrigerant, duty, evaporating temperature, redundancy and controls are specified. Qualify the design intent, then issue one RFQ.

Supplier-neutral. Free for buyers and project owners. Best suited to commercial projects from USD $250,000.